Anticoagulants: Warfarin
Videos
Notes
Emergency medicine
Medical and surgical emergencies
AssessmentsAnticoagulants: Warfarin
Flashcards
Anticoagulants: Warfarin
Anticoagulants: Warfarin exam links
Content Reviewers:
Yifan Xiao, MD, Maria Emfietzoglou, MD, James Schurr, PharmDContributors:
Evan Debevec-McKenney, Marisa Pedron, Robyn Hughes, MScBMC, Ursula Florjanczyk, MScBMC, Sean Watts, MDAnticoagulant medications are used to prevent blood clots from forming. These medications work by interfering with the normal function of plasma proteins called coagulation factors, which take part in secondary hemostasis. But let’s focus specifically on the anticoagulant warfarin, which works by preventing the synthesis of coagulation factors II, VII, IX and X, and anticoagulation proteins C and S. Now, to understand the regulation of clot formation we first need to talk briefly about hemostasis-- in which hemo refers to the blood, and stasis means to halt or stop. Hemostasis is divided into two phases: primary and secondary hemostasis.
Primary hemostasis involves the formation of a platelet plug around the site of an injured blood vessel, and secondary hemostasis reinforces the platelet plug with the creation of a protein mesh called fibrin. To get to fibrin, a set of coagulation factors each of which or enzymes need to be activated. These enzymes are activated via a process called proteolysis- which is where a portion of the protein is clipped off. In total, there are twelve coagulation factors numbered factors I-XII, but there’s no factor VI. Most of these factors are produced by liver cells, and it turns out that producing coagulation factors II, VII, IX, and X requires an enzyme that uses vitamin K.
Now, when vitamin K is absorbed from the digestive tract and travels to the liver, it’s in its dietary form and it’s called vitamin K quinone. An enzyme, called quinone reductase, takes electrons from NADPH, and donates them to vitamin K quinone, converting it into the reduced form which is called vitamin K hydroquinone. Then, vitamin K hydroquinone acts as a cofactor by donating its electrons to an enzyme called gamma glutamyl carboxylase, which converts the non-functional forms of coagulation factors II, VII, IX, and X into their functional forms. Gamma glutamyl carboxylase adds a carboxyl group, which is a chemical group made up of one carbon, and two oxygens, onto the end of glutamic acid residues on the proteins.
After the carboxylation step, vitamin K is in an oxidized form, where it can accept electrons, and it’s called vitamin K epoxide. Vitamin K epoxide gets converted back into vitamin K quinone by another enzyme called vitamin K epoxide reductase, or VKOR, which donates electrons to vitamin K epoxide using a thiol group. In this fashion, a single molecule of vitamin K can be reused many times. As it turns out, the drug warfarin, which was first used as a rat poison, blocks the function of this enzyme which blocks vitamin K from getting recycled and as a result factors II, VII, IX, and X don’t get activated.
Now let's take a closer look at the coagulation cascade to see where these coagulation factors play their respective roles. The coagulation cascade begins via two pathways --the extrinsic and intrinsic pathways. The intrinsic pathway starts when circulating factor XII comes into contact with the surface of activated platelets or collagen. Activated factor XII, then activates factor XI, which activates factor IX which activates factor X. Factor X starts the common pathway where it activates factor II, which activates factor I that builds the fibrin mesh. When factor II gets activated it also activates 4 other factors: V, VIII, IX, and XIII. Factor V gets activated and acts as a cofactor for X, factor VIII acts as a cofactor for factor IX, and factor XIII helps factor I, or fibrin, form crosslinks.
In the extrinsic pathway, exposed tissue factors on the damaged blood vessel activates factor VII, which activates factor X and starts the common pathway. So without vitamin K, the loss of factor VII means that the extrinsic pathway won’t function; the same goes for factor IX; and without factor X and II, the common pathway won’t function. Warfarin is taken per-oral and it affects the extrinsic pathway first since factor VII has the shortest half life and it’s the first coagulation factor to run out. Next, levels of factor II, IX, and X also drop, causing inhibition of the intrinsic and common pathways. Since factor VII drops first, warfarin’s efficacy is monitored using a blood test called prothrombin time, or PT, which is a measure of how well the extrinsic and common pathways are functioning. To perform this test, blood is drawn and the plasma is separated out by centrifuge. The plasma contains all the coagulation factors minus tissue factor, which is normally found within the blood vessel walls.
- "Katzung & Trevor's Pharmacology Examination and Board Review,12th Edition" McGraw-Hill Education / Medical (2018)
- "Rang and Dale's Pharmacology" Elsevier (2019)
- "Goodman and Gilman's The Pharmacological Basis of Therapeutics, 13th Edition" McGraw-Hill Education / Medical (2017)
- "Overview of hemostasis" J.C. Aster, H. Bunn (Eds.), Pathophysiology of Blood Disorders, 2e. McGraw-Hill. (2016)
- "Nomograms" D. Nicoll, C. Mark Lu, S.J. McPhee (2017)
- "Ischemic Stroke: Risk Stratification, Warfarin Teatment and Outcome Measure" J Atr Fibrillation (2015)
- "Critical Issues and Recent Advances in Anticoagulant Therapy: A Review" Neurology India (2019)