Dose limits for exposure to ionizing radiation: Rad Tech
Radiation dose limits are upper boundaries of exposure to ionizing radiation for imaging personnel and the public to minimize the risk of harmful biologic effects. These include equivalent dose or EqD, which applies to a specific tissue or organ and accounts for the type of radiation; and effective dose, or EfD, which combines doses to different organs, like the eyes and skin, with their relative sensitivity. Both are expressed in millisieverts, or mSv. Importantly, a dose limit serves as an upper boundary rather than a target or a dividing line between safe and dangerous exposure.
Organizations, including the International Commission on Radiological Protection, or ICRP, and the National Council on Radiation Protection and Measurements, or NCRP, and Nuclear Regulatory Commission, or NRC, evaluate evidence and recommend radiation protection standards for occupational and nonoccupational exposure to ionizing radiation. These standards are used by radiologic technologists along with facility policies.
Now, dose limits vary according to who is being protected. Occupational limits apply to medical imaging workers, while public limits apply to people whose exposure is unrelated to their job. For patients, limits are managed separately since the radiation involves diagnostic or therapeutic procedures. So, patient exposure is based on justification, meaning each exam or treatment is clinically appropriate; and optimization, meaning the radiation dose used in the examination is kept As Low as Reasonably Achievable, or ALARA.
Whole-body dose limits apply to occupational exposure to radiation workers such as radiologic technologists. Under current regulations, the annual effective dose limit for an adult radiation worker is 50 mSv.
Cumulative guidelines traditionally compare an individual's career effective dose by multiplying 10 mSv by their age in years to establish the cumulative effective dose limit to the whole body. Importantly, this cumulative value is a long-term reference rather than a target. Occupational exposure should remain well below the maximum allowable limit by following appropriate radiation protection practices. These values also exclude natural background radiation, and any dose the technologist may receive as a patient.
In addition to the whole-body dose limit, there are separate annual limits that apply to specific tissues. Under current U.S. regulations, the lens of the eye has an annual limit of 150 mSv, while the skin and extremities, including the hands and feet, have an annual limit of 500 mSv.