Sterile technique and aseptic procedures: Rad Tech

Ver video solo

Sterile technique and aseptic practices are essential for radiologic technologists. These practices help prevent the spread of microorganisms during invasive and surgical imaging procedures. As a radiologic technologist, you need to understand how to protect patients from pathogenic microorganisms that can spread through contact with the environment, healthcare personnel, and medical equipment. Knowing how to apply these practices helps reduce the risk of infection and supports patient safety throughout the procedure.

Sterile technique may also be used during interventional procedures, surgical imaging, and procedures involving sterile supplies, dressings, tubes, or lines.

There are some radiology procedures that require the use of sterile technique and aseptic practices. These include invasive procedures that involve entering the body or exposing normally sterile areas that could be contaminated with microorganisms. Examples include angiography, myelography, and biopsy procedures.

These procedures may require a sterile field, which is a designated area, such as a sterile tray or towel, that contains the sterile supplies and equipment needed for the procedure and is considered free from microorganisms.

Sterile fields should always be established as close as possible to the time of the procedure. The longer a sterile field remains open, the greater the risk of contamination from airborne microorganisms. Once established, the sterile field should stay in view and be continually monitored to prevent accidental contamination.

Only sterile items and personnel wearing sterile attire can safely interact with the sterile field. Because contamination is not always visible, sterile technique is based on the principle that any questionable item or area should be treated as contaminated. For example, any item that falls below waist level or extends outside the sterile field is considered contaminated and should not be used.

To create the field, a sterile drape or sterile package is opened carefully on a clean, dry surface. Before you establish a sterile field, you must inspect the sterile package to confirm that packaging is intact, dry, and within the expiration date. Damage to packaging or evidence of moisture may indicate contamination.

The edges of the wrapper are unfolded away from the body first, and the inner surface is kept untouched because it becomes the sterile area.

Sterile supplies are then placed onto the center of the field without reaching across it or letting nonsterile items touch it.

When opening sterile supplies, care must be taken to avoid introducing microorganisms into the field. Once opened, sterile items are placed within the sterile field and should only come into contact with other sterile items or personnel wearing sterile attire.