Sterile technique and aseptic procedures: Rad Tech

Sterile technique and aseptic practices are essential for radiologic technologists. These practices help prevent the spread of microorganisms during invasive and surgical imaging procedures.
As a radiologic technologist, you'll need to understand how to protect patients from pathogenic microorganisms that can spread through contact with the environment, healthcare personnel, and medical equipment.
Knowing how to apply these practices helps reduce the risk of infection and supports patient safety throughout the procedure.
Sterile technique may also be used during interventional procedures, surgical imaging, and procedures involving sterile supplies, dressings, tubes, or lines.
There are some radiology procedures that require the use of sterile technique and aseptic practices. These include invasive procedures that involve entering the body or exposing normally sterile areas that could be contaminated with microorganisms.
Examples include angiography, myelography, and biopsy procedures. These procedures may require a sterile field, which is a designated area such as a sterile tray or towel that contains the sterile supplies and equipment needed for the procedure and is considered free from microorganisms.
Sterile fields should always be established as close as possible to the time of the procedure. The longer a sterile field remains open, the greater the risk of contamination from airborne microorganisms.
Once established, the sterile field should stay in view and be continually monitored to prevent accidental contamination.
Only sterile items and personnel wearing sterile attire can safely interact with the sterile field. Because contamination is not always visible, sterile technique is based on the principle that any questionable item or area should be treated as contaminated.
For example, any item that falls below waste level or extends outside the sterile field is considered contaminated and should not be used.
To create the field, a sterile drape or sterile package is opened carefully on a clean dry surface. Before you establish a sterile field, you must inspect the sterile package to confirm that packaging is intact, dry, and within the expiration date.
Damage to packaging or evidence of moisture may indicate contamination. The edges of the wrapper are unfolded away from the body first, and the inner surface is kept untouched because it becomes the sterile area.
Sterile supplies are then placed onto the center of the field without reaching across it or letting non-sterile items touch it.
When opening sterile supplies, care must be taken to avoid introducing microorganisms into the field. Once opened, sterile items are placed within the sterile field and should only come into contact with other sterile items or personnel wearing sterile attire.
Maintaining the integrity of the sterile field requires constant attention throughout the procedure, moisture, unnecessary movement.
Prolonged exposure to air or contact with non-sterile surfaces can compromise sterility. For example, if fluid splashes onto the sterile field and causes strike through contamination, the field is considered contaminated and must be replaced.
Assisting with a sterile imaging procedure begins with hand hygiene and surgical hand asepsis, also known as a surgical scrub.
The purpose of the scrub is to reduce microorganisms on the hands and forearms before participating in a sterile procedure.
Jewelry and other items that may harbor microorganisms are removed before the scrub begins. After the surgical scrub is completed, care must be taken to avoid contact with non-sterile surfaces.
You'll use sterile drying techniques, gowning and gloving to establish and maintain a sterile barrier during the procedure.
When putting on a sterile gown, keep in mind that only the inner surfaces of the gown should be touched to maintain sterility.
The front of the gown is considered sterile, while the back of the gown is not sterile. Since the back of the gown is not considered sterile, sterile team members should keep the sterile field in view and avoid turning their backs toward it.
A non-sterile team member will typically assist in securing the gown from behind to help preserve the sterile field. Sterile gloves are then applied to create a protective barrier between you and the sterile field.
During gloving, pay close attention to which surfaces remain sterile and which areas become contaminated through contact.
Once gowning and gloving are complete. Maintain sterile awareness throughout the procedure to avoid contaminating the sterile field.
As a radiologic technologist, you may perform imaging for patients who have medical devices such as tracheostomies, chest tubes, urinary catheters, or peripheral intravenous or central lines.
During imaging procedures, care must be taken to avoid contaminating, dislodging, or damaging the device. A tracheostomy is an artificial airway consisting of a small plastic tube inserted through an opening in the front of the neck to help a patient breathe.
Imaging may be performed to confirm correct tube placement or evaluate complications such as airway obstruction or air leaks.
When caring for patients with tracheostomies, observe for signs of respiratory distress or excessive secretions and report concerns to the appropriate healthcare provider.
Care should be taken to avoid pulling or disrupting the airway device during positioning. A chest tube is used to remove air, blood, or fluid from around the lungs to help the lungs expand properly.
Imaging is commonly used to verify placement and evaluate lung expansion after insertion. During imaging and patient transport, avoid tension on the tubing and ensure that the drainage collection system always remains below the level of the insertion site.
Some patients undergoing imaging may have an indwelling urinary catheter, which is a tube inserted into the bladder to drain urine.
To reduce the risk of infection, the drainage bag should remain below the level of the bladder and should never rest on the floor during imaging procedures or transport.
Many patients will also have intravenous or arterial lines. These lines may be used to deliver medications and fluids or to monitor cardiovascular function in critically ill patients.
Imaging is often used to confirm proper line placement during positioning and movement. Special care must be taken to avoid pulling, kinking, or dislodging these lines.
Imaging performed in surgical and procedural environments requires careful attention to sterile technique. During these procedures, radiologic technologists and sonographers work closely with the surgical team while maintaining awareness of the sterile field and avoiding contamination of sterile equipment and supplies.
Fluoroscopic imaging systems such as a C arm are commonly used during surgery to provide real-time imaging that helps guide instruments and visualize anatomy during procedures.
Intraoperative ultrasound may also be used to evaluate soft tissues, identify structures, or assist with image-guided procedures.
Because imaging equipment is not typically sterile, protective sterile barriers are often used during procedures. For example, image receptors, ultrasound transducers, and portions of imaging equipment may be covered with sterile drapes or covers before entering the procedure area.
Equipment is then positioned by sterile team members to help maintain the integrity of the sterile field. Sometimes radiographic image receptors can be placed under the operating table through a tunnel device.
Lastly, the contaminated waste must be removed safely to protect patients and staff. Disposable items contaminated with blood or body fluids are placed in the appropriate biohazard container or bag.
Sharps, such as needles or scalpel blades must be placed directly into an approved sharps container and should never be recapped, bent, or carried loose.
Soiled dressings and contaminated disposable supplies should be handled with gloves and discarded according to facility policy.
All reusable equipment must be cleaned of visible soil and then disinfected or returned for reprocessing. After handling contaminated material, remove gloves safely and perform hand hygiene.
All right, as a quick recap, sterile technique and aseptic practices are essential for radiologic technologists. These practices help prevent the spread of microorganisms during invasive and surgical imaging procedures.
As a radiologic technologist, you need to understand how to protect patients from pathogenic microorganisms that can spread through contact with the environment, healthcare personnel, and medical equipment.
Knowing how to apply these practices helps reduce the risk of infection and supports patient safety throughout the procedure.